• The solid block-off tool is used in the left bank high-pressure oil rail only.
• It enables you to eliminate the left high-pressure oil rail and the left bank injectors while testing the integrity of the remaining high-pressure oil system.
• ICP pressure is measured using the ICP sensor installed in the right bank high- pressure oil rail or the right bank block-off tool.
• NOTE: Both block-off tools can be used at the same time to eliminate both high-pressure oil rails and all eight injectors. ICP pressure/voltage will be monitored using the ICP sensor installed in the right bank block-off tool, the ICP break-out harness (as pictured above), and the WDS.