6.4L 392 HEMI V-8 – SOLENOID, VARIABLE VALVE TIMING (VVTS), EXHAUST – REMOVAL

NOTE:
The Variable Valve Timing Solenoid (VVTS) (3) is located under the intake manifold.

1. Remove intake manifold. Refer to MANIFOLD, INTAKE, REMOVAL.

2. Disconnect VVTS electrical connector (1).

3. Remove VVTS retaining bolt (2).

NOTE: To remove the VVTS, the engine must be at room temperature.

4. Rotate the VVTS to break the seal and remove.