Inspect all crankcase breather tubes internally for obstructions or sludge buildup.
If a tube is blocked, it must be cleaned with a strong solution of detergent or replaced to prevent excess crankcase pressure buildup.
Dry the crankcase breather tube with compressed air.
Check the crankcase breather tubes for cracks. Replace any damaged crankcase breather tubes.