NOTE: If installing a new turbocharger, orient the compressor housing to the same position as the
turbocharger that was removed. Orient the housing by loosening the v-band clamp and then positioning the
housing in the correct location. Do not orient the turbine housing.
Torque Value: 8 Nโขm [ 71 in-lb ]
Apply a film of high-temperature anti-seize compound to the turbocharger mounting studs.
Only remove Clean Care caps as the connections are being made.
Use a new gasket and install the turbocharger.
Install and tighten the four mounting nuts.
NOTE: The torque values given have been established using anti-seize compound as a lubricant.
Torque Value: 55 Nโขm [ 41 ft-lb ]