6.7L Cummins Air Intake System – Variable Geometry Turbocharger Actuator, Electric – Remove

Disconnect the wiring harness from the turbocharger actuator by sliding the locking tang to the open position,
then push down on the release lever and pull the connection apart.
Remove the turbocharger actuator mounting capscrews, with a 5 mm Allen wrench and discard the capscrews.
Remove the actuator.
Remove and discard the turbocharger actuator sealing gaskets.