6.7L Cummins Electrical Equipment – Starting Motor – Install

For engines with wet flywheel housings, apply a 1.5 to 2.0 mm [0.06 to 0.09 in] wide bead of sealant, Part Number
3164067, to the flywheel housing starting motor mounting flange.
NOTE: If a starting motor spacer is required, make sure to apply sealant to the side of the spacer that contacts the
starting motor.

Install the three capscrews, the starting motor, and starting motor spacer (if required).
Torque Value: 43 Nโ€ขm [ 32 ft-lb ]

NOTE: Use the location tags to help identify where each wire connection goes.
Connect the electrical connections to the starter motor.

NOTE: Use the location tags to help identify where each wire connection goes.
Install the starter motor electrical connections.
For Non-Cumminsยฎ branded starters, refer to the Original Equipment Manufacturer (OEM) manual for torque
specifications.