The lower hydraulic coupler piston moves the control valve down to relieve high pressure from the top of the nozzle needle (the control chamber).
When the control valve is pushed fully down, it seals off an orifice in the intermediate plate, stopping that fuel flow path of high pressure fuel to the top of the nozzle needle. Fuel is allowed to flow past the control valve, also removing pressure from the top of the nozzle needle.