6.7L Power Stroke – Volume Control Valve (VCV)


The fuel VCV is mounted on the high pressure fuel pump. The PCM controls the volume of low pressure fuel
that enters the inlet one-way check valve and two main pump pistons by activating the fuel VCV.
The PCM regulates fuel volume by controlling the on/off time of the fuel VCV solenoid. A high duty cycle indicates less volume is being commanded. A low duty cycle indicates a high fuel volume is being commanded.