8 mm
Remove the electrical wire and complete the following steps.
Clean around the valve.
24 mm
Remove the valve.
NOTE: The Bosch VE valve is shown. The valve for Lucas CAV is located at the bottom of the pump.
Caution: When removing the valve, be careful not to drop the plunger and spring.
โPackageโ the solenoid, o-ring, spring and plunger.
24 mm
Tighten the solenoid securely.
Connect the electric wire.
Torque Value: 43 N*m [32 ft-lb]