#201 Inspection of relay (normally open, 5 pins)
โข Perform a continuity check and an operation check. If there is any abnormality, replace the relay.
#318 Inspection of boost pressure sensor
โข Apply 5 volts DC to terminals 3 and 1.
โข Apply air pressure. Gradually increase it and, while doing so, measure the output voltage occurring at terminals 2 and 1.
โข If any measurement is out of specification, replace the sensor.
#514 Inspection of turbocharger actuator
โข Perform the following checks. If there is any abnormality, replace the turbocharger actuator.
(1) Coil resistance of motor
โข Measure the resistance between terminals 8 and 7, the resistance between terminals 8 and 6, and the resistance between terminals 7 and 6.
(2) Position sensor
โข The sensor cannot easily be inspected in isolation, so you must evaluate it indirectly by inspection of system harnesses and related parts.
โข lf there is no abnormality in any related part but the system is abnormal, replace the turbocharger actuator.
#828 Inspection of controller area network resistor
โข Measure the resistance between terminals 1 and 2.
โข If the measurement is out of specification, replace the controller area network resistor.