John Deere – 1023E, 1025R and 1026R – Fuel Shutoff Circuit Diagnosis 1023E and 1025R

CONDITIONS:
– Machine parked, park brake locked
– Battery fully charged
– Power and Crank Circuits tested and functioning
– Transmission in NEUTRAL
– PTO switch OFF
– Digital voltmeter (–) lead to battery negative post
– Digital voltmeter (+) lead to designated test point
– Key switch position as directed

Refer to Cranking and Starting Circuit – 1023E or Cranking and Starting Circuit – 1025R for circuit schematics.

→NOTE:
In rare cases, the instrument cluster may be faulty. Test all applicable power, grounds, wires, connectors and components before replacing ICC.