KOHLER KDW 702 – Oil pump – Reassembly

The pump rotors should be coupled on the same side, see references 2 and 3.
Replace the O-ring 1.

๏‚ฆTighten the fastening screws to the crankcase at 25 Nm and those of the plate at 10 Nm.