KUBOTA – L2501 – HYDRAULIC SYSTEM – DISASSEMBLING AND ASSEMBLING – Lift Arm, Hydraulic Arm and Hydraulic Arm Shaft

1. Disconnect the position control rod from feedback lever.
2. Remove the lift arm setting screws.
3. Draw out the hydraulic arm shaft (5) and right lift arm (6) as a unit.
4. Take out the hydraulic arm (1).
5. Remove the collar (3) and O-ring (2).
(When reassembling)
โ€ข Align the alignment marks of the hydraulic arm and hydraulic arm shaft (7).
โ€ข Align the alignment marks of the lift arm and hydraulic arm shaft (8).
โ€ข Apply grease to the right and left bushings of hydraulic cylinder block and O-rings (2).
โ€ข Take care not to damage the O-ring (2).