KUBOTA – L2501 – HYDRAULIC SYSTEM – SERVICING – Operating Pressure of Cylinder Safety Valve

1. Attach the cylinder safety valve to injection nozzle tester with a safety valve setting adaptor.
2. Measurement the operating pressure of the cylinder safety valve.
3. If the operating pressure is not within the factory specifications, adjust by turning the adjusting screw (1).
4. After adjustment, tighten the lock nut (2) firmly.
NOTE
โ€ข Use specified transmission fluid (See page G-9) to test the operating pressure of the cylinder safety valve.