1. To install, reverse removal procedure. Using the Spring Gauge (211-034, T74P-3504-Y), adjust the actuator rod length to obtain the specified reading. The butterfly valve should be fully closed when 10 lbs. (4.5 kg) of force is applied with the spring gauge. See Fig. 97.
Tighten fasteners to specification. See TORQUE SPECIFICATIONS.