7.3L Power Stroke – BACK PRESSURE VALVE – Installation

1. To install, reverse removal procedure. Using the Spring Gauge (211-034, T74P-3504-Y), adjust the actuator rod            length to obtain the specified reading. The butterfly valve should be fully closed when 10 lbs. (4.5 kg) of force is            applied with the spring gauge. See Fig. 97.
Tighten fasteners to specification. See TORQUE SPECIFICATIONS.